Adjusting AIR SUPPLY CONTROL
1) Select “MIN” or “MAX” using slide switch (A).
When “MIN” (minimum speed) is selected, if the knob (B)
is set above the click, the unit will exchange in low
speed with the outside and if it is set below the click,
the unit will exchange on high speed with the outside
until the desired humidity level has been reached.
When “MAX” (maximum speed) is selected, the unit will
exchange on high speed with the outside either if the
knob is set below or above the click.
2) To turn off the unit, slide the switch at the “OFF” position.
Adjusting DEHUMIDISTAT
Setting during the summer months:
During this period, unless being afflicted with breathing problems, using the Dehumidistat is
unnecessary. Set the slide switch to “OFF”. (Do not exchange in day time; exchange at night
time, if cool outside, or if it is not raining.)
Setting during the fall, winter and spring months:
(When severe condensation appears on windows)
1) Determine the humidity level in your house (bring the knob (B) counterclockwise to its
maximum position, then bring it back clockwise slowly until you hear a “click”).
2) Set the knob to one line under this temperature level or “click”.
2. CONTROLS (CONTD)
2.6 BRONZE MAIN CONTROL (FOR 90H-V UNIT ONLY)
16
CAUTION
Do not select a temperature below -20°C (-4°F). This could lead to excessive
dryness in the air causing discomfort for the occupants.
It is possible (and normal) to experience condensation on your windows when drastic
changes in temperature happen (for example: -5°C [23°F] to -20°C [-4°F]). In that case,
we suggest waiting a few days to allow the situation to stabilize.
2.7.1 20-MINUTE LIGHTED PUSH-BUTTON (FOR 90H-V UNIT ONLY)
Press once to activate the push button. The unit will operate on
high speed for 20 minutes and the indicator will light up. To stop
activation before the end of the 20-minute cycle, push one more
time. The unit will get back to its previous setting.
VENTILATION
®
VC0040
ON
2.7 OPTIONAL AUXILIARY CONTROLS
Contrary to the main controls, up to 5 optional auxiliary controls can be connected to the
same ventilation unit.
C
O
M
F
O
R
T
Z
O
N
E
O
F
F
%
R
E
L
A
T
I
V
E
H
U
M
I
DIT
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY
CONTROL
DURING FALL, WINTER
AND SPRING, SET THE
DIAL ACCORDING TO
THE DESIRED MAXIMUM
INDOOR HUMIDITY LEVEL.
DURING SUMMER SET
THE DIAL TO THE
OFF POSITION.
VC0039
MIN.
MAX.
OFF
M
O
R
E
H
U
M
I
D
L
E
S
S
H
U
M
I
D
C
O
M
F
O
R
T
Z
O
N
E
-30°C
-22°F
-20°C
-4°F
-5°C
23°F
5°C+
41°F+
B
A